摘要
Abstract
Due to its features in long transmission distance and high voltage grade, traditional relay protection scheme cannot meet the requirement of half wave-length AC transmission (HWACT). Considering distributed parameter characteristic of half wave-length AC transmission line, by use of the characteristic equation of uniform transmission line and integrating with symmetrical component, the fault characteristics of HWACT line inside and outside the protction zone are theoretically analyzed, and simulation results show that the results from theoretical derivation basically conform with actual conditions. According to fault characteristics of HWACT line, a new Bergeron model based current differential protection strategy suit to HWACT line is proposed and PSCAD platform based time-domain simulation experiments for the proposed protection strategy are performed. Experiment results show that when various kinds of short-circuit faults occur inside the protection zone, the amplitudes of different currents at both sides of the position where fault occurs are far bigger than those of short-circuit faults occur outside the protection zone, thus the current differential protection for HWACT line can act correctly.关键词
半波长交流输电/贝瑞隆模型/继电保护/电流差动保护Key words
half wave-length AC transmission/Bergeron model/relay protection/cusrent differential protection分类