To study the shear strength of anchorage adhesive under high temperature, 57 specimens were tested. The test temperature ranges from 25℃ to 350℃. The specimens were heated by the electric furnace. When heated to the fixed temperature, the specimen was tested. Five specimens were tested in each temperature. In the test, records were made on the furnace temperature, specimen temperature, slip and the force. The test results show that the shear strength decreases with temperature increasing, and the shear strength is about 4% of that in the ambient temperature when the temperature is above 350℃