| 注册
首页|期刊导航|高压电器|基于超高频法的典型GIS局部放电检测

基于超高频法的典型GIS局部放电检测

孙曙光 陆俭国 俞慧忠 沈建位 金少华

高压电器2012,Vol.48Issue(4):7-12,6.
高压电器2012,Vol.48Issue(4):7-12,6.

基于超高频法的典型GIS局部放电检测

Detection of Typical GIS Partial Discharge Based on UHF Method

孙曙光 1陆俭国 2俞慧忠 1沈建位 2金少华2

作者信息

  • 1. 河北工业大学,天津300130
  • 2. 浙江开关厂有限公司,衢州324000
  • 折叠

摘要

Abstract

GIS partial discharge detection is a scientific and effective way for insulation condition monitoring. A GIS model and the detection system based on UHF method has been set up. Several typical GIS partial discharge is studied and using power phase analysis a detailed analysis of characteristics under different voltage is made; Combined with conventional partial discharge detection method, the partial discharge quantity estimation of UHF signal is also made. All of these lay a foundation for the study of partial discharge intelligent recognition and the relationship between UHF signal and partial discharge quantity to improve the engineering utility of UHF partial discharge detection.

关键词

GIS/局部放电/超高频/相位分析/放电量

Key words

gas insulated switchgear/ partial discharge/ UHF/ power phase analysis/ discharge quantity