摘要
Abstract
A test-bed of air-source heat pump water heater was set up. The experiment compared the system' s performance in the standard conditions using casing condenser, three casing condenser and plate condenser respectively. The results show that the plate condenser' s performance which used in the heat pump water heater system is much better than the other two conventional heat exchangers. The system' s performance coefficient reached to 4. 1 when using plate condenser, which is higher than the system ' s performance using the other two kinds of condenser by about 20 percent. The results provide an experimental basis to how to improve the performance of the heat pump water heaters system.关键词
直热式/空气源/热泵热水器/性能系数Key words
directly heated/air-source/heat pump water heater/COP分类
通用工业技术引用本文复制引用
郭志敏,朱兴旺,王朝鑫,苏宇贵..直热式热泵热水器冷凝器结构优化试验研究[J].流体机械,2012,40(1):70-72,3.