摘要
Abstract
By the instantaneously variable load experiments of different load rising rate, the amplitude, wave frequency and the coal consumption analysis in the 1 036 MW unit of Huaneng Haimen Power Plant were implemented. The results show that the coal consumption rate of rising load conditions was bigger than that of stable load conditions, and the coal consumption rate of dropping load conditions was smaller than that of stable conditions. The bigger the load fluctuation was, the bigger the coal consumption rate fluctuation was. The optimal rising load rate and the optimal scheduling mode were gained. The economical efficiency of unit operation was improved and the coal consumption rate was reduced. The experiments result can provide a theoretical basis for the energy saving, emission reducing, optimal operation mode and the energy saving scheduling.关键词
超超临界/瞬变负荷/动态能耗/供电煤耗率/节能Key words
ultra supercritical/ instantaneously variable load/ dynamic energy consumption/ coal consumption rate/ energy saving分类