摘要

Abstract

In order to analyze the influence of grounding locations on the shielding effectiveness (SE) of shielded room, numerical simulation is done by applying par-allel time-domain finite-difference (FDTD) method on the coupling problems between shielded room and two high power electromagnetic environments, that arelightning electromagnetic pulse (LEMP) and altitude electromagnetic pulse (HEMP), respectively. Inner coupled electromagnetic (EM) fields are calculatedwhen the shielded room is with different grounding locations. The results indicate that the farther the distance between the grounding location and the aperture, the better the SE of shielded room.

关键词

并行时域有限差分算法/屏蔽效能/接地位置/高功率电磁环境

Key words

parallel time-domain finite-difference method shielding effectiveness/grounding locations high power electromagnetic environment