辐射防护2012,Vol.32Issue(3):177-180,4.
成都地区室内氡浓度调查
Investigation of Indoor Radon Concentration in Chengdu
摘要
Abstract
Solid state nuclear track method was used to measure indoor radon concentrations in 100 rooms of different construction structures, decoration materials and floors in Chengdu. The results showed that the highest level of indoor radon concentration in Chengdu is 177.1 Bq/m3, the lowest level is 8.4 Bq/m3, and the average level is (39.4 ±22.9) Bq/m3; Statistical analyses showed that the differences of indoor radon concentration among different types of building were significant; Radon and his daughter's annual effective dose to shine is 0.99 mSv, lower than world average.关键词
室内氡浓度/建筑/有效剂量Key words
indoor radon concentration/building/effective dose分类
医药卫生引用本文复制引用
徐立鹏,葛良全,曾兵,谷懿,姜海静,罗耀耀,熊超..成都地区室内氡浓度调查[J].辐射防护,2012,32(3):177-180,4.基金项目
国家自然科学基金资助项目(编号:41074093). ()