Besides electrical and mechanical design for thyristor valve, one of the key equipments for high voltage DC power transmission project, choose of electrical components is also an important work. With the development of high power electronic devices,techniques and stability of the electrical components have been substantially improved and thyristors of 6 inches have been commonly used in thyristor valves for ultra high voltage DC power transmission projects. Before put into operation,dielectric type test on thyrisotr valve should be done to verify dielectric performance of thyristor valve. This paper is a study on non-periodic firing test which is included in dielectric type test on ±1 100 kV UHVDC thyrisotr valve. Non-periodic firing test is the most severe test on thyristor valve.whose purpose is to verify if valve can withstand impulse current on switching impulse voltage, and to test if VCM can properly protect thyristors during turn-on and turn-off.The writer studies on the non-periodic firing test for ±1 100 kV thyristor valve with PSCAD stimulation software.which shows that single valve can stand impulse current of about 6 045 A when required switching impulse voltage of 574.4 kV is applied on single valve.

关键词

特高压直流输电/换流阀/VCM/PSCAD/操作冲击/冲击电流

Key words

ultra high voltage DC power transmission/ thyrisotr valve/ VCM/ PSCAD/switching impulse/ impulse current

分类

信息技术与安全科学

引用本文复制引用

班建,李侠,行鹏,胡宇,李强..±1 100kV/5 000A特高压直流输电换流阀非周期触发试验仿真研究与试验验证[J].高压电器,2012,48(6):34-37,4.

高压电器

OA北大核心CSCDCSTPCD

1001-1609

访问量0
|
下载量0
段落导航相关论文