摘要
Abstract
Objective: To analyze long R-R intervals in ambulatory electrocardiography(AECG)(expect atrial fibrillation in full time),and to probe into the significance of clinical and the cause of long interval.Methods: Retrospective analysis of 65 cases of R-R interval ≥2.0 s in 2 500 AECGs from the June 2009 to the June 2011 was made,and various types of pathogens of long R-R intervals and their electrocardiogram changes were collected.Results: The occurrence of long R-R intervals was 2.60 %(65/2 500).Patients over 50 years old accounted for 92.30%(60/65),and common pathogens were coronary heart disease,high blood pressure.The electrocardiogram changes which cause long intervals were ranged in descending order as sinus arrest 43.08%(28/65),blocked premature atrial contraction 20.00 %(13/65),artrioventricular block(Mobitz typeⅡ) 18.46 %(12/65),artrioventricular block(Mobitz typeⅠ) 10.77 %(7/65),sinoatrial block 3.08%(2/65),compensatory pause after atrial tachycardia 3.08 %(2/65),complete artrioventricular block 1.53 %(1/65).Conclusion: 24 hours AECG is a secure and effective examination for long R-R intervals.The pathogens of long intervals and various types of electrocardiogram changes have been found out,which is significant for clinical job.关键词
24小时动态心电图/长R-R间期/病因学Key words
24 hours ambulatory/long R-R interval/electrocardiography(AECG)分类
医药卫生