| 注册
首页|期刊导航|计算机工程|一种基于AD检验的CFAR检测器

一种基于AD检验的CFAR检测器

徐从安 简涛 孙伟超 顾新锋

计算机工程2012,Vol.38Issue(9):231-233,3.
计算机工程2012,Vol.38Issue(9):231-233,3.DOI:10.3969/j.issn.1000-3428.2012.09.071

一种基于AD检验的CFAR检测器

CFAR Detector Based on Anderson-Darling Test

徐从安 1简涛 1孙伟超 2顾新锋1

作者信息

  • 1. 海军航空工程学院信息融合研究所,山东烟台264001
  • 2. 海军航空工程学院研究生管理大队,山东烟台264001
  • 折叠

摘要

Abstract

For solving the robust disadvantage of the existing Constant False Alarm Rate(CFAR) detectors, a new CFAR detector based on Anderson-Darling(AD) test called AD-CA is proposed. It takes the critical value of AD test through Monte Carlo simulation, then deletes the unwanted samples. It is evaluated through simulation in various environments. Simulation result shows that, in homogeneous background, the performance of AD-CA is as good as OS; In multiple targets background, compared with the OS, the detection performance of AD-CA improves obviously. Especially when the value of interfering targets exceeds N-k, it also keeps good performance.

关键词

雷达/目标检测/多目标背景/恒虚警率/AD检验

Key words

radar/ target detection/ multiple targets background/ Constant False Alarm Rate(CFAR)/ Anderson-Darling(AD) test

分类

信息技术与安全科学

引用本文复制引用

徐从安,简涛,孙伟超,顾新锋..一种基于AD检验的CFAR检测器[J].计算机工程,2012,38(9):231-233,3.

基金项目

国家自然科学基金资助项目(60672140) (60672140)