| 注册
首页|期刊导航|能源研究与管理|容克式空预器单侧停运改进措施

容克式空预器单侧停运改进措施

匡仁钦 万斌 佘宏飞

能源研究与管理Issue(2):37-38,47,3.
能源研究与管理Issue(2):37-38,47,3.

容克式空预器单侧停运改进措施

Remedial Measures of One-side Ljungotroem Air Heaters Shut Downs

匡仁钦 1万斌 2佘宏飞3

作者信息

  • 1. 赣能股份有限公司江西丰城二期发电厂,江西丰城331100
  • 2. 江西省科学院能源研究所,南昌330029
  • 3. 江西江联能源环保股份有限公司,南昌330001
  • 折叠

摘要

Abstract

The operation of one-side ljungotroem air heaters shut downs in 700 MW unit was analyzed, problems of rotary air preheaters were described, and their origin was analyzed. Some suggestions for improvement were introduced, and the security and efficiency of operation were increased greatly.

关键词

空预器/容克式/消缺/分析/改进措施

Key words

preheater/ljungstrom/eliminate fault/analysis/remedial measures