强激光与粒子束2012,Vol.24Issue(3):571-575,5.DOI:10.3788/HPLPB20122403.0571
多间隙气体开关绝缘子寿命
Lifetime of insulator used for multi-gap gas switch
摘要
Abstract
This paper summarizes an experimental study on lifetime of the insulator used for multi-gap gas switch. The mechanism of the insulator lifetime being reduced because of pollution is analyzed. The distribution of static electric field on insulator surface is simulated. The change of self-breakdown voltage and surface resistance due to pollution is experimentally obtained. After 13 000 shots under the discharge current of 32 kA, the self-breakdown voltage reduces from 171.5 to 130. 8 kV and the surface resistance reduces from 200 to 22. 6 GΩ, which means the insulator can not operate normally. The measures for prolonging lifetime of the insulator are put forward.关键词
快前沿直线脉冲变压器/多间隙气体开关/自击穿电压/绝缘子Key words
fast linear transformer drivers multi-gap gas switch/self-breakdown voltage/insulator分类
信息技术与安全科学引用本文复制引用
孙铁平,丛培天,曾正中,黄涛,王亮平..多间隙气体开关绝缘子寿命[J].强激光与粒子束,2012,24(3):571-575,5.基金项目
西北核技术研究所预研基金项目(11030707) (11030707)