水力发电2012,Vol.38Issue(2):71-73,3.
油压装置自动补气异常分析及处理
Analysis and Troubleshooting on the Abnormal Operation of Automatic Air Compensation Device for Oil Pressure Unit
李金明 1唐杰阳 2虎勇 1吴光明 1常学东1
作者信息
- 1. 锦屏水力发电厂,四川西昌615012
- 2. 二滩水力发电厂,四川攀枝花617000
- 折叠
摘要
Abstract
The automatic air compensation device of No. 5 oil pressure unit in Ertan Hydropower Plant frequently occurs abnormal operation. By using the statistics data of IMS, the operation is quantitatively analyzed and compared with the operation of other units. The reason and law of abnormal air compensation operation are found out, and the maintenance strategy is developed and the troubleshooting and test are also conducted. The following operation shows that the device is back to normal.关键词
油压装置/自动补气/异常/故障处理Key words
oil pressure unit/ automatic air compensation/ abnormal operation/ troubleshooting分类
能源科技引用本文复制引用
李金明,唐杰阳,虎勇,吴光明,常学东..油压装置自动补气异常分析及处理[J].水力发电,2012,38(2):71-73,3.