| 注册
首页|期刊导航|沈阳工业大学学报|1000MW水轮发电机不对称运行时阻尼条涡流损耗计算分析

1000MW水轮发电机不对称运行时阻尼条涡流损耗计算分析

梁艳萍 孙洋 陈晶 孙玉田

沈阳工业大学学报2012,Vol.34Issue(2):138-143,6.
沈阳工业大学学报2012,Vol.34Issue(2):138-143,6.

1000MW水轮发电机不对称运行时阻尼条涡流损耗计算分析

Calculation and analysis on eddy current loss of damping bar under asymmetrical operation of 1 000 MW hydro-generator

梁艳萍 1孙洋 1陈晶 1孙玉田2

作者信息

  • 1. 哈尔滨理工大学电气与电子工程学院,哈尔滨150080
  • 2. 哈尔滨大电机研究所,哈尔滨150040
  • 折叠

摘要

Abstract

Aiming at the phenomenon that the damping bars would easily fuse under the asymmetrical operation of large hydro-generator, the eddy current loss of damping bars under the asymmetrical operation of a 1 000 MW hydro-generator was further studied on the basis of establishing two-dimensional electromagnetic field-circuit-motion coupled time-stepping finite element model. The influence of such factors as the stator slotting, magnetic pole rotation and stator current on the eddy Current loss of damping bars were comprehensively considered. The eddy current loss of each damping bar in one magnetic pole under different operating conditions was accurately calculated, and the change rule of eddy current loss was analyzed. And thus, the influence of the connection mode of damping system as well as the radius and material of damping bar on the eddy current loss of damPing bars was discussed. The results indicate that the eddy current loss of last damping bar along the rotation direction is the largest, and the structure parameters of damping system have greater influence on the distribution of eddy current loss of damping bars.

关键词

1000/MW水轮发电机/不对称运行/阻尼条/涡流损耗/数值计算/阻尼方式/阻尼条半径/阻尼条材料/t

Key words

1 000 MW hydro-generator/asymmetrical operation/damping bar/eddy current loss/numerical calculation/damping mode/damping bar radius/damping bar material

分类

信息技术与安全科学

引用本文复制引用

梁艳萍,孙洋,陈晶,孙玉田..1000MW水轮发电机不对称运行时阻尼条涡流损耗计算分析[J].沈阳工业大学学报,2012,34(2):138-143,6.

基金项目

“十一五”国家科技支撑计划重大资助项目(2007BAA05B06). ()

沈阳工业大学学报

OA北大核心CSTPCD

1000-1646

访问量0
|
下载量0
段落导航相关论文