中国组织工程研究2012,Vol.16Issue(22):4067-4070,4.DOI:10.3969/j.issn.1673-8225.2012.22.018
髋臼横断骨折双柱内固定的生物力学分析
Biomechanical analysis of double-column internal fixation on acetabular transverse fracture
摘要
Abstract
BACKGROUND: The key of pelvic and acetabular fracture treatment is accurate fracture reduction and stable internal fixation.OBJECTIVE: To analyze the biomechanical characteritics of three kinds of double-column internal fixation operation foracetabular transverse fracture in order to find the most stable method.METHODS: Anisotropic pelvic fracture model was established, and based on the maximum displacement, the maximumequivalent stress and other comprehensive evaluation indexes, the biomechanics of double-column screw, anterior-columnscrew and posterior-column plate, double-column plate on the standing position were analyzed.RESULTS AND CONCLUSION: Finite element analysis showed that the maximum displacement of double-column screw was1.827 mm, maximum equivalent stress was 26.589 Mpa; the maximum displacement of screw and posterior-column plate was2.080 mm, maximum equivalent stress was 106.04 Mpa; the maximum displacement of double-column plate was 2.987 mm,maximum equivalent stress was 200.37 Mpa. The most stable method is double-column screw and the last one is double-columnplate.关键词
髋臼/横断骨折/内固定/有限元建模/生物力学分类
医药卫生引用本文复制引用
吴淑琴..髋臼横断骨折双柱内固定的生物力学分析[J].中国组织工程研究,2012,16(22):4067-4070,4.基金项目
国家自然科学基金项目资助(30870603). (30870603)