压力容器2012,Vol.29Issue(4):62-67,6.DOI:10.3969/j.issn.1001-4837.2012.04.010
12Cr1MoVG换热管泄漏失效原因分析
Leak Reason Analysis of 12Cr1MoVG Heat Exchange Tubes
徐书根 1赵延灵 1王宗明1
作者信息
- 1. 中国石油大学(华东)化学工程学院,山东青岛266555
- 折叠
摘要
Abstract
In order to analyze the leak reason of the heat exchange tube which is made of 12CrlMoVG,the appearance of corrosion, metallographic structure, chemical composition of the tube material and the corrosion products,and service environment have been analyzed. The results show that the uniform corrosion which induced by the Oxygen and high temperature vapor occurred. The tube wall has been partially perforated in the serious corrosion area. The prevention methods were proposed for this equipment.关键词
泄漏/失效分析/12Cr1MoVG/换热管Key words
leak/failure analysis/12CrlMoVG/heat exchange tube分类
机械制造引用本文复制引用
徐书根,赵延灵,王宗明..12Cr1MoVG换热管泄漏失效原因分析[J].压力容器,2012,29(4):62-67,6.