Abstract

The operating experience shows that the parallel gap device (PGD) can effectively reduce the insulator damage caused by the lightning strike. However, the insulating co-ordination research between the insulator and the parallel gap device at high altitude areas is still inadequate. For this reason, the standard negative lightning flashover characteristics and voltage-time (V-t) characteristics experiments on a 220 kV composite insulator, a 220kV porcelain insulator string and their parallel gap devices were carried out in the National Engineering Laboratory (Kunming) for UHV Engineering Technology. Based on the test results, the flashover and V-t characteristics effect of PGDs on different insulators were analyzed. By combining the insulating co-ordination regulation with arc paths, the optimal distances for PGDs protection of the insulator strings were obtained. The result indicates that, the electric-field distribution of insulator affects the lightning flashover characteristics of PGDs; the recommended PGDs have excellent protective function to insulator strings.

关键词

绝缘子串/并联间隙/伏秒特性/绝缘配合

Key words

insulator string/parallel gap device (PGD)/voltage-time characteristics/insulating co-ordination

分类

信息技术与安全科学

引用本文复制引用

司马文霞,叶轩,谭威,杨庆,罗兵,李立浧,高超..高海拔220kV输电线路绝缘子串与并联间隙雷电冲击绝缘配合研究[J].中国电机工程学报,2012,32(10):168-176,9.

基金项目

重庆市科委自然科学基金计划面上项目(CSTC2011BB6065). ()

中国电机工程学报

OA北大核心CSCDCSTPCD

0258-8013

访问量0
|
下载量0
段落导航相关论文