Abstract

The air-staged and low NO, combustion technology in a 600 M W tangential firing boiler was researched. The comparison of nitrogen oxide emission concentration before and after the reformation was analyzed. The results show that the NO, emission concentration of boiler was reduced obviously. The NO, emission concentration was reduced about 50% when the unit load was over 350 MW. The results of the operation adjustment test show that the SOFA air flow, auxiliary air damper opening, secondary air box and furnace differential pressure have larger influence on NO, emission.

关键词

四角切圆燃烧/锅炉/低NOx燃烧改造/运行调整

Key words

tangential firing/boiler/low NO, combustion reformation/operation adjustment