| 注册
首页|期刊导航|中国电力|西门子技术1000MW超超临界机组轴系振动问题

西门子技术1000MW超超临界机组轴系振动问题

张学延 张卫军 葛祥 何国安

中国电力2012,Vol.45Issue(5):68-72,80,6.
中国电力2012,Vol.45Issue(5):68-72,80,6.

西门子技术1000MW超超临界机组轴系振动问题

Vibration of turbine shafting in 1000 MW ultra supercritical unit with Simens technology

张学延 1张卫军 1葛祥 1何国安1

作者信息

  • 1. 西安热工研究院有限公司,陕西西安710032
  • 折叠

摘要

Abstract

The layout features of the unit shafting and their effects on shafting vibration and evaluation index were introduced for 1 000 M W ultra supercritical units with Simens technology. Based on the vibration diagnosis and treatment for more than 10 units, some typical vibration faults were summarized, such as the vibration fluctuation of the high pressure (HP) rotor, abnormal vibration increasing of No.3 bearing pedestal and big vibration of the exciter rotor during its critical range of speeds. The vibration characteristics, the causes of faults and countenneasures were analyzed. Three applications were analyzed. The vibration fault identification method, control measures and applications can provide a reference for vibration diagnoses and treatments of the same type units.

关键词

超超临界/振动/单支承/转子(热)不平衡/转子动(热)平衡

Key words

ultra supercritical unit/vibration/single bearing support/rotor (thermal) unbalance/rotor dynamic (thermal) balance

分类

能源科技

引用本文复制引用

张学延,张卫军,葛祥,何国安..西门子技术1000MW超超临界机组轴系振动问题[J].中国电力,2012,45(5):68-72,80,6.