| 注册
首页|期刊导航|中国医学装备|Uritest-830型半自动生化分析仪故障分析与排查

Uritest-830型半自动生化分析仪故障分析与排查

杨德武 董谦 杜娟

中国医学装备2012,Vol.9Issue(2):83-85,3.
中国医学装备2012,Vol.9Issue(2):83-85,3.

Uritest-830型半自动生化分析仪故障分析与排查

Maintenance and analysis of breakdowns for semi-automatic biochemical analyzerI

杨德武 1董谦 1杜娟1

作者信息

  • 1. 北京卫生学校影像学科,北京100053
  • 折叠

摘要

Abstract

Objective: Uritest-830 semi-automatic biochemical analyzer is an advanced, compact and practical biochemical instrument. In this paper, we discussed the analysis and trouble-shooting ways of breakdowns of this instrument. Methods: On the basis of analyzing and fault recognition of this biochemistry analyzer, this paper introduces the structure and operating principle of the circuit, functional test of electric components, and judgment of the testing results. Results: according to operating principle, many common breakdowns can be resolved. It not only greatly improves the efficiency of the machine, but also ensures daily clinical operations. Conclusion: This Paper briefly describes the t~henomenon, analysis andmaintenance of common breakdown for Uritest-830 semiautomatic biochemical analyzer, so as to summarize the experience of efficient technical operations.

关键词

生化分析/基本结构/故障分析/排查维修

Key words

Biochemical analysis/Basic structure/Fault analysis/Maintenance

分类

医药卫生

引用本文复制引用

杨德武,董谦,杜娟..Uritest-830型半自动生化分析仪故障分析与排查[J].中国医学装备,2012,9(2):83-85,3.

中国医学装备

OACSTPCD

1672-8270

访问量0
|
下载量0
段落导航相关论文