原子能科学技术2012,Vol.46Issue(5):627-632,6.
某轻混凝土γ屏蔽积累因子的计算
Calculation of γ Shielding Buildup Factor for Certain Light Concrete
张雷 1YUKIO Sakamoto 2赵兵 1王学新 1张建岗1
作者信息
- 1. 中国辐射防护研究院,山西太原030006
- 2. 日本原子力研究所,日本茨城县东海村3191195
- 折叠
摘要
Abstract
Exposure buildup factors up to 40 mean free paths in ranging from 0. 015 MeV to 15 MeV photon energy were calculated by using the Monte Carlo simulation code EGS4 for light concrete used in certain nuclear power plant. The calculation took into account effect of bremsstrahlung, fluorescence and coherent (Rayleigh) scattering on the buildup factor. Then, the corresponding fitting parameters of the G-P fitting formula were presented by the geometrical progression approximation fitting formula. The method can get the γ shielding buildup factors for any shielding thickness of the concrete and any photon energy.关键词
屏蔽/积累因子/EGS4/G-P近似/轻混凝土Key words
shielding/ buildup factor/EGS4/ G-P approximation/ light concrete分类
数理科学引用本文复制引用
张雷,YUKIO Sakamoto,赵兵,王学新,张建岗..某轻混凝土γ屏蔽积累因子的计算[J].原子能科学技术,2012,46(5):627-632,6.