摘要

Abstract

The frequency dependent network equivalent (FDNE) based electromagnetic and electromechanical hybrid simulation system can not simulate the faults on the electromechanical network side. Firstly, a hot standby method was proposed to initialize the state variables of the new FDNE to decrease the spurious transient during the swap. Secondly, an electrical distance index was proposed to quickly determine the necessity of the swap of the FDNE. Thirdly, an electrical distance index based FDNE-swapping strategy was proposed to save computational burden. Several systems are used as the examples to demonstrate the accuracy and efficiency of the proposed electrical distance index based FDNE-swapping method.

关键词

临界电气距离指标/电磁暂态/机电暂态/故障后/的频率相关网络等值/初始化

Key words

critical electrical distance index/electromagnetic transient/electromechanical transient/frequency dependent network equivalent post fault/initialization