中国电力2012,Vol.45Issue(6):35-38,4.
260t/h循环流化床锅炉秸秆混烧试验
Straw co-combustion experiment in a 260 t/h circulating fluidized bed boiler
李斌 1李建锋 2高志宏 2郭晓飞 3尧国富 3张全胜 2杨迪 2王元2
作者信息
- 1. 华北电力大学 能源动力与机械工程学院,北京 102206
- 2. 中国电力企业联合会 科技开发服务中心,北京 100055
- 3. 洛阳龙羽宜电有限公司,河南 洛阳 471000
- 折叠
摘要
Abstract
Because of the small installation capacity, the straw consumption ratio of power generation in biomass power plant was very big. The co-combustion technology of thermal power units was an effective measure to reduce the initial investment and to improve the efficiency of biomass energy. The results of co-combustion industrial experiment in a 260t/h circulating fluidized bed (CFB) boiler unit show that if the amount of biomass co-combustion was less than 30% (mass ratio), the co-combustion has no apparent disadvantageous effect on the operation performance of unit. And the pollutant emission concentrations decreased with the increasing of the amount of co-combustion.关键词
混烧/生物质能/循环流化床/工业试验Key words
co-combustion/ biomass energy/ circulating fluidized bed/ industrial experiment分类
能源科技引用本文复制引用
李斌,李建锋,高志宏,郭晓飞,尧国富,张全胜,杨迪,王元..260t/h循环流化床锅炉秸秆混烧试验[J].中国电力,2012,45(6):35-38,4.