| 注册
首页|期刊导航|中国医学装备|尿液分析仪的测试原理与故障排除

尿液分析仪的测试原理与故障排除

赵磊

中国医学装备2012,Vol.9Issue(5):81-82,2.
中国医学装备2012,Vol.9Issue(5):81-82,2.

尿液分析仪的测试原理与故障排除

Clinical application and maintenance of urine analyzer

赵磊1

作者信息

  • 1. 天津市第四医院设备科,天津300222
  • 折叠

摘要

Abstract

Objective: To introduce the testing principle, composition, clinical application and troubleshooting methods of urine analyzer. Methods: We analyzed and cleared fault in some cases such as the instrument is not self-test, the screen display and test results showed "error" no content by understanding the testing principles and structure, combined with maintenance of the equipment. Results: It has been ensured that the instrument can be used normally through the maintenance and repair of equipment. Conclusion: In the daily use of urine analyzer, engineer should be familiar with the instrument, its analyzing principles and strengthen the routine maintenance to ensure that the instruments work in the best condition to maximize the strengths of urine analyzer, improve urine analysis quality and speed up the rate of equipment maintenance.

关键词

尿液分析仪/测试原理/故障排除

Key words

Urine analyzer/Testing principle/Troubleshooting

分类

机械制造

引用本文复制引用

赵磊..尿液分析仪的测试原理与故障排除[J].中国医学装备,2012,9(5):81-82,2.