Abstract
By introducing the requirements of time synchronization (TS), the technical characteristics, operation principle and the networking methods of network time protocol in smart substations, the advantages and shortages of the network TS system are analyzed. To solve the potential security risks of system management, product design and network architecture caused by IEC 61588 network TS system, a security evaluation method based on the simulation technique under network traffic for smart substation is proposed. The proposed method has been used to analyze a case, and the safe and reliable operation of the IEC 61588 TS system is ensured.关键词
智能变电站/IEC61588/网络时间协议/风险分析/安全评估Key words
smart substation/IEC 61588/network time protocol/risk analysis/security evaluation分类
信息技术与安全科学引用本文复制引用
黄鑫,王永福,张道农,李芹,卞宝银..智能变电站IEC61588时间同步系统与安全评估[J].电力系统自动化,2012,36(13):76-80,5.