环境工程学报2012,Vol.6Issue(7):2271-2275,5.
建立数学模型分析UV-Fenton对金属切削液废水的降解
Establishing mathematic model to analyze degradation of metalworking fluids by UV/Fenton
摘要
Abstract
Abstract The metalworking fluids wastewater was treated by UV/Fenton. The optimum conditions deter- mined by the orthogonal experiment and single-factor experiment were as follows : pH = 2.5, Fe2 + adding capacity of 24.8 mmol/L, H2 02 ( concentration of 30% ) adding capacity of 127.5 mL/L and adding 6 times during the to- tal reaction time of three hours. Under the conditions, the COD removal rate could reach to 95%. Finally, using the 1st Opt software to make multiple non-linear fitting, it could establish the mathematic model equation of the COD removal rate of the MWFs by UV/Fenton, and then analyzed and discussed it.关键词
数学模型/金属切削液/UV/Fenton/COD去除率Key words
mathematic model/metalworking fluids (MWFs)/UV/Fenton/COD removal rate分类
资源环境引用本文复制引用
凰乃磊,王中琪,徐旭东..建立数学模型分析UV-Fenton对金属切削液废水的降解[J].环境工程学报,2012,6(7):2271-2275,5.基金项目
科技部中欧科技合作项目 ()
四川省环境工程自控技术高校重点实验室资助 ()