辐射防护2012,Vol.32Issue(5):259-264,272,7.
ARCON96在核电站主控室可居留性评价中的应用及其与组合尾流模式的对比
Application of ARCON96 in NPP Control Room Habitability Assessment and Its Comparison with Composite Wake Model
方晟 1李红 1方栋1
作者信息
- 1. 清华大学核能与新能源技术研究院,北京100084
- 折叠
摘要
Abstract
ARCON96 is the current NRC-recommended atomospheric dispersion model that may be used to estimate atmospheric relative concentration in assessing the habitability of a NPP control room during design basis radiological events.Based on meteorological data from a NPP site in China,the atmospheric relative concentration was calculated and analyzed using ARCON96,and then compared with calculations by the composite wake model.Results demonstrated that ARCON96 is feasible for atmospheric relative concentration estimation and its estimate is more conservative than the composite wake model.关键词
主控室可居留性/大气弥散因子/ARCON96/组合尾流模式Key words
control room habitability/atmospheric relative concentration/ARCON96/composite wake model分类
能源科技引用本文复制引用
方晟,李红,方栋..ARCON96在核电站主控室可居留性评价中的应用及其与组合尾流模式的对比[J].辐射防护,2012,32(5):259-264,272,7.