高电压技术2012,Vol.38Issue(7):1642-1647,6.
高密封性等离子体发生器一致性实验研究
Experimental Study on Consistency of High Leakproofness Plasma Generator
摘要
Abstract
Capillary discharge plasma generator is a key component in electrothermal chemical (ETC) guns, and its performance has a great influence on the ignition process. The working consistency is the basis for optimization of the plasma generator, and it is a necessary premise in realizing the advantages of ETC guns. In order to evaluate and optimize the working consistency, parallel experiments were carried out on a conventional generator with electrical parameters in discharge and iet pressure as the characterization parameters. Results reveal that there are large deviations among parallel tests. Besides, severe ablation and plenty of carbon powder can be found in the generator, indicating that the poor consistency is closely related to the internal breakdown caused by the lack of leakproofness. In order to prevent internal breakdown, a new electrode structure with special section was proposed. Results of evaluation experiments demonstrate that the new design can improve the leakproofness considerably and realize better output consistency compared with the original design.关键词
毛细管放电/等离子体发生器/密封性/一致性/电热化学炮/结构优化Key words
capillary discharge/plasma generator/leakproofness/consistency/electrothermal chemical gun/structure optimization分类
信息技术与安全科学引用本文复制引用
张玉成,李兴文,李瑞,贾申利,刘强..高密封性等离子体发生器一致性实验研究[J].高电压技术,2012,38(7):1642-1647,6.基金项目
燃烧与爆炸技术重点实验室基金(编号略). ()