| 注册
首页|期刊导航|环境工程学报|甲苯在两相厌氧系统中降解及其抑制作用

甲苯在两相厌氧系统中降解及其抑制作用

王文文 李爱民 吴伟 李文涛

环境工程学报2012,Vol.6Issue(8):2755-2758,4.
环境工程学报2012,Vol.6Issue(8):2755-2758,4.

甲苯在两相厌氧系统中降解及其抑制作用

Toluene degradation and its inhibition effect in two-stage anaerobic digestion system

王文文 1李爱民 1吴伟 1李文涛1

作者信息

  • 1. 南京大学环境学院污染控制与资源化研究国家重点实验室,南京210046
  • 折叠

摘要

Abstract

The two-stage anaerobic digestion process was introduced to treat wastewater containing toluene. With the increase of toluene concentration, the system still ran stably and efficiently. When the toluene concen- tration was lower than 20 rag/L, the COD removal efficiency and production of VFA in acidogenic stage were sig- nificantly inhibited and then recovered to the previous level after a period of domestication. When the toluene concentration was higher than 150 rag/L, the COD removal efficiency in methanogenie reactor was significantly inhibited and began to decline sharply. High concentration of toluene stimulated microbial macromolecules' pro- duction, so that substances of high molecular weight increased in effluent. The toluene was degraded up to 99% easily even though its concentration increased to 200 mg/L.

关键词

两相厌氧系统/甲苯/降解/抑制

Key words

two-stage anaerobic digestion/toluene/degradation/inhibition

分类

资源环境

引用本文复制引用

王文文,李爱民,吴伟,李文涛..甲苯在两相厌氧系统中降解及其抑制作用[J].环境工程学报,2012,6(8):2755-2758,4.

基金项目

江苏省环保科研课题项目 ()