航天器环境工程2012,Vol.29Issue(3):320-322,3.DOI:10.3969/j.issn.1673-1379.2012.03.017
空间真空环境下密封电磁继电器的触点失效研究
The contact failure of hermetically sealed electromagnetic relays used in space vacuum environment
摘要
Abstract
The leakage rate is an inherent property of hermetically sealed electromagnetic relays. When used in the space vacuum environment, the relay's inner gas will progressively release and its inner pressure will be reduced gradually. As a result, the relay's contact points may be switched into a low pressure environment and the contact failure may occur. In order to verify such mechanism, some homemade relay samples are selected and the contact switching experiments are conducted. The arc failure laws of the relay's contact point switching in a low inner pressure are studied.关键词
电磁继电器/低气压环境/继电器触点/电弧放电/试验研究/可靠性Key words
electromagnetic relay/low pressure environment/relay's contact/arc discharge/experimental study/reliability分类
信息技术与安全科学引用本文复制引用
张磊,黄俊才,杨剑,肖忠英..空间真空环境下密封电磁继电器的触点失效研究[J].航天器环境工程,2012,29(3):320-322,3.基金项目
"十一五"国防基础科研项目"空间环境下卫星长寿命评估、验证与保障技术研究"(编号:D0320060537) (编号:D0320060537)