电力系统保护与控制2012,Vol.40Issue(13):151-155,5.
110kV智能变电站典型接线型式的IED配置方案研究
Study on IED configuration scheme corresponding to typical connection modes in I10 kV intelligent substation
袁文广 1刘益青 1孙十柱 2魏欣1
作者信息
- 1. 积成电子股份有限公司,山东济南250100
- 2. 山东大学电气工程学院,山东济南250061
- 折叠
摘要
Abstract
In order to standardize the configuration schemes of IED (intelligent electronic device), this paper researches the typical configuration of secondary equipments in 110 kV intelligent substations. With the features of fixed operation modes, there are four typical connection modes in 110 kV substations, including inner bridge connection, line transformer unit connection, extended inner bridge connection and sectionalized single bus connection. Then the typical IED configuration schemes in process-level and bay-level are presented respectively. The schemes have the following characteristics: the merging units digitize analog information collected by conventional instrument transformers; process level information is exchanged by peer-to-peer model; the transformer protection, including merging unit, adopts a redundant configuration scheme; a distributed configuration using the IED with integrated functions of process-level and bay-level is implemented in middle or low voltage bays. The engineering practice shows that this scheme can guide intelligent reconstruction of conventional substation with its economy and advanced technology.关键词
智能变电站/智能电子设备/过程层/间隔层/配置方案Key words
intelligent substation/ intelligent electronic device/ process level/ bay level/ configuration scheme分类
信息技术与安全科学引用本文复制引用
袁文广,刘益青,孙十柱,魏欣..110kV智能变电站典型接线型式的IED配置方案研究[J].电力系统保护与控制,2012,40(13):151-155,5.