煤矿安全2012,Vol.43Issue(8):11-13,3.
晋城矿区采动区煤层气地面井抽采技术试验
Test of Coal Bed Gas Ground Well Extraction Technology in Mining Subsidence Area of Jincheng Mining Area
摘要
Abstract
The coal bed gas ground well extraction test of mining subsidence area in 4308 working face of Chengzhuang coal mine in Jincheng city was done. Aiming at the geological characteristics of the test point, the body structure of test well was designed, and the drilling extraction datum before and after working face passed through were analyzed. The casing deformation were investigated four times. The test found that the extration pure flow of ground well reached to 8 m3/min. But, how to maintain the stability of casing is still a problem which should be resolved.关键词
地面井/煤层气抽采/采动影响区/套管损坏/防护措施Key words
Found well/coalbed gas extraction/infection zones of coal mining/casing damage/protective measures分类
矿业与冶金引用本文复制引用
李日富,文光才,司鹄..晋城矿区采动区煤层气地面井抽采技术试验[J].煤矿安全,2012,43(8):11-13,3.基金项目
基金项目:大型油气田及煤层气开发科技重大专项资助项目 ()