贺军

宁夏电力Issue(3):55-57,3.
宁夏电力Issue(3):55-57,3.

330MW发电机组凝结水泵振动原因分析及处理

Vibration Cause analysis and treatment of condensate pump for 330 MW generating set

贺军1

作者信息

  • 1. 国电宁夏英力特宁东煤基化学有限公司热电公司,宁夏灵武750411
  • 折叠

摘要

Abstract

Aiming at the problems of big vibration for frequency conversion moto:r after the conden- sate pump rebuild, tests and analyzes the vibration, through the way of dynamic balancing and increas- ing rigidity of the shell of motor, eliminates the vibration. The result shows that the causation of con- densate pump vibration is due to the connection way leading to the shafting rigidity decrease and hap- pen resonance.

关键词

凝结水泵/变频改造/振动

Key words

eondensate pump/frequency conversion rebuild/vibration