| 注册
首页|期刊导航|现代检验医学杂志|便携式血糖仪与生化分析仪血糖检测结果的相关性研究

便携式血糖仪与生化分析仪血糖检测结果的相关性研究

孙虹 苏敏 蒋杰 牛华 蒋红君

现代检验医学杂志2012,Vol.27Issue(2):77-79,3.
现代检验医学杂志2012,Vol.27Issue(2):77-79,3.DOI:10.3969/j.issn.1671-7414.2012.02.027

便携式血糖仪与生化分析仪血糖检测结果的相关性研究

Correlation Studies of Glucose Testing Results between Portable Blood Glucose Meter and Biochemical Analyzer

孙虹 1苏敏 1蒋杰 1牛华 1蒋红君1

作者信息

  • 1. 云南省第一人民医院检验科暨云南省临床检验中心,昆明650032
  • 折叠

摘要

Abstract

Objective To investigate the glucose testing results correlation between portable blood glucose meter and biochemical analyzer by comparing the testing results of three different modes of portable blood glucose meters and biochemical analyzer. Methods With reference to the protocol of venous sample comparison from < the management and clinical practices of portable blood glucose monitoring device in medical institution (Trail) ), 50 cases of heparin anti-coagulation venous whole blood were collected. Whole blood glucose was measured by glucose meter firstly,and then the remaining samples were cen-trifuged immediately to get plasma. The plasma glucose was tested by biochemical analyzer within 30 minutes. The correlation coefficients and deviations were calculated from the results between three glucose meters and biochemical analyzer and also the relevant analysis was conducted. Results The within-run CV of three glucose meters was between 1. 28% and 4. 87%. The intra-day imprecision of low concentration QC material was s <0.13 mmol/L. The CV of middle and high concentration QC material was between 1. 28% and 4. 87%,which meet the precision requirement of the specification. The results coefficients of these two different testing equipments ( r) were higher than 0. 98. The slope of linear regression equation b>l. 0±0. 05 and for samples which the glucose concentration was between 2. 3 and 4. 2 mmol/L, the percentages of testing results within the acceptable error(±0. 83 mmol/L) were 60%,30% and 80% for Sure Step,Performa and Active blood glucose meter, respectively. While for samples which the glucose concentration was between 4. 6 and 22. 6 mmol/L, the percentage of testing results within the acceptable error was between 95% and 97. 5%. Conclusion Results of three portable glucose meters were all correlated very well with those of biochemical analyser and meet the requirement of the specification. But results of glucose meters were lower than biochemical analyser,generally. The results deviation of glucose meters and biochemical analyser could meet the requirement of the specification only when the glucose concentration was higher than 4. 2 mmol/L, which means biochemical analyzer should be used to re-test the low concentration glucose sample.

关键词

便携式血糖仪/生化分析仪/血糖/偏差/相关性

Key words

portable glucose meter/precision/accuracy/deviation/correlation

分类

医药卫生

引用本文复制引用

孙虹,苏敏,蒋杰,牛华,蒋红君..便携式血糖仪与生化分析仪血糖检测结果的相关性研究[J].现代检验医学杂志,2012,27(2):77-79,3.

现代检验医学杂志

OACSTPCD

1671-7414

访问量0
|
下载量0
段落导航相关论文