| 注册
首页|期刊导航|西安交通大学学报(医学版)|选择性应用陶瓷人工骨在椎体后凸成形中预防骨水泥渗漏的作用

选择性应用陶瓷人工骨在椎体后凸成形中预防骨水泥渗漏的作用

杨益民 任志伟 李萌 张智 王金堂 王莹

西安交通大学学报(医学版)2012,Vol.33Issue(4):494-497,4.
西安交通大学学报(医学版)2012,Vol.33Issue(4):494-497,4.

选择性应用陶瓷人工骨在椎体后凸成形中预防骨水泥渗漏的作用

Cement leakage prevention in kyphoplasty by selectively applying bioceramic bone granules

杨益民 1任志伟 1李萌 1张智 1王金堂 1王莹1

作者信息

  • 1. 西安交通大学医学院第一附属医院骨科,陕西西安710061
  • 折叠

摘要

Abstract

To selectively apply calcium phosphate cement to percutaneous kyphoplasty (PKP) to study its effect in preventing cement leakage. Methods From June 2009 to May 2011, a total of 116 patients with fresh vertebral fracture in which vertebral body anterior lateral wall was defected to different degrees by CT scan were randomly allocated into two groups. The control group was treated with normal PKP procedure and the experiment group with PKP in addition to bioceramic bone granules. We recorded the weight of bone granules, the volume of cement injection and leakage rate and outcome. We assessed pain severity < VAS scale) and the height compression rate of anterior vertebrae (Lee method), measured kyphosis angle (Cobb method) before and after surgery; CT scans were taken to observe the postoperative cement leakage. Results PKP was successfully performed in all the patients. Fifty-eight cases were chosen in the experiment group planted with bioceramic bone granules (2.83±1.67 g, bone cement volume of 3,74±0.66 mL). There were totally 5 cement extrusions, with a leakage rate of 3,4%. The average VAS improvement after operation was 6-14 ±0, 95; anterior vertebral height compression rate was improved by 21.74±1.99%, and kyphotic angle was improved by 23.72±2.33. Postoperative CT scan showed that bone granules were filled well in the anterior of vertebrae. Another 58 cases were treated in the control group with bone cement volume of 4.01 ±0,61 mL. There were 8 (13.8%) leakages out of 58. Analysis with SPSS 17. 0 statistic software showed significant differences in bone cement planted and cement leakage rate between the two groups (P<0.05). However, the two groups did not significantly differ in VAS scores, restoration rate of anterior vertebral height or kyphosis angle (P>0. 05). Conclusion Our findings suggest that bioceramic bone granules selectively applied to PKP not only is effective but also can reduce the volume of cement injection and decrease the incidence of cement leakage.

关键词

椎体/压缩性骨折/椎体后凸成形术/陶瓷人工骨/骨水泥渗漏

Key words

vertebras compression fractures kyphoplasty/ bioceramic bone granule/ cement leakage

分类

医药卫生

引用本文复制引用

杨益民,任志伟,李萌,张智,王金堂,王莹..选择性应用陶瓷人工骨在椎体后凸成形中预防骨水泥渗漏的作用[J].西安交通大学学报(医学版),2012,33(4):494-497,4.

基金项目

西安市科技计划项目(No.SF09029) (No.SF09029)

西安交通大学学报(医学版)

OA北大核心CSCDCSTPCD

1671-8259

访问量0
|
下载量0
段落导航相关论文