| 注册
首页|期刊导航|压力容器|稳压器波动管温度监测及寿命评估

稳压器波动管温度监测及寿命评估

李岗 梁兵兵 马志才

压力容器2012,Vol.29Issue(6):63-67,5.
压力容器2012,Vol.29Issue(6):63-67,5.DOI:10.3969/j.issn.1001-4837.2012.06.012

稳压器波动管温度监测及寿命评估

Temperature Monitoring and Life Evaluation for Pressurizer Surge Line

李岗 1梁兵兵 1马志才1

作者信息

  • 1. 上海核工程研究设计院,上海200233
  • 折叠

摘要

Abstract

As one of the important equipment insuring the integrity of primary loop pressure boundary, surge line suffers the thermal stratification loads besides varies transient loads during its life time. In order to obtain the actual thermal stratification data,a temperature monitoring system are designed. Based on the real thermal stratification data, bounding up design transients, the fatigue life of a specific surge line and its tee were evaluated including thermal stratification effects. Suggestions of surge line stratification monitoring and life evaluation are provided.

关键词

波动管/热分层/热振荡/寿命评估

Key words

surge line/ thermal stratification/ thermal stripping/ life evaluation