中国临床医学2012,Vol.19Issue(3):268-269,2.
克氏针交叉内固定治疗肱骨髁上骨折的疗效分析
Open Reduction and Crossed Kirschner-Wire Fixation of Supracondylar Humerus Fractures
王云才 1戴文达2
作者信息
- 1. 云南省昭通市中医院外科,云南昭通 657000
- 2. 复旦大学附属中山医院骨科,上海200032
- 折叠
摘要
Abstract
Objective: To investigate the efficacy of open reduction and crossed Kirschner-wire (K-wire) fixation in supracon-dylar humerus fractures. Methods: A total of 42 patients with supracondylar humerus fractures were treated by open reduction and crossed k-wire fixation. Results: The 42 cases in this study were followed up from 5 to 36 months,the average follow-up time was 12. 16 ± 5. 31 months. Functional outcome was assessed with the use of mazur scoring system. The results were excellent in 28 patients,good in 11,fair in 2,and poor in 1. Among the 42 patients,92. 9% were rated as excellent or good. Conclusions; Treatment of supracondylar humerus fractures with crossed K-wire fixation can achieve good results.关键词
克氏针/交叉内固定/肱骨髁上骨折Key words
Kirschner-wire/Crossed fixation/Supracondylar fracture of the humerus分类
医药卫生引用本文复制引用
王云才,戴文达..克氏针交叉内固定治疗肱骨髁上骨折的疗效分析[J].中国临床医学,2012,19(3):268-269,2.