The defrosting time, discharge pressure, indoor temperature fluctuations and other defrosting characteristics of air source heat pump were experimentally investigated at three defrosting modes, i.e., reverse cycle defrosting, hot gas bypass defrosting and phase change material defrosting. The results showed that the performance of phase change material defrosting system is better than the others. The phase change material has increased the discharge temperature and the condensing temperature, which benefits to the decrease of defrost time and energy consumption, and the indoor temperature is relatively stable.

关键词

热工学/除霜性能/比较/逆循环除霜/热气旁通除霜/相变蓄能除霜/空气源热泵

Key words

Pyrology/ Defrosting performance/ Comparison/ Reverse cycle defrosting/ Hot-gas bypass defrosting/ Phase change material defrosting/ Air source heat pump