铸造技术2012,Vol.33Issue(5):555-557,3.
电站锅炉高温炉烟管道断裂分析
Analysis on Fracture of High Temperature Flue Duct of Boiler in Power Plant
郑坊平 1崔雄华 1李梁 1王碧磊1
作者信息
- 1. 西安热工研究院有限公司,陕西西安710032
- 折叠
摘要
Abstract
By means of chemical composition analysis, mechanical properties testing, metallographic examination and fracture analysis, the fracture reason of the flue duct of boiler in a power plant was analyzed. The results show that the fracture of the flue duct is brittle fracture, because the strength of the material is not worth to bear regular loading, under the condition of many casting flaws existing, the mechanical properties are tar away below the standard request关键词
炉烟管道/铸造缺陷/脆性断裂Key words
flue duct of boiler/ casting flaw/ brittle fracture分类
金属材料引用本文复制引用
郑坊平,崔雄华,李梁,王碧磊..电站锅炉高温炉烟管道断裂分析[J].铸造技术,2012,33(5):555-557,3.