现代农业科技Issue(5):270-273,278,5.
日光温室后屋面内侧温度变化规律及温度预测模型
Change of Temperature of Back Roof in Greenhouse and Forecasting Model
何雨 1须晖 2李天来 2山口智治3
作者信息
- 1. 辽宁省沈阳棋盘山开发区管理委员会,辽宁沈阳110161
- 2. 沈阳农业大学园艺学院、辽宁省设施园艺重点实验室
- 3. 筑波大学农业与森林工程研究所
- 折叠
摘要
Abstract
Measurement and analysis were conducted on temperature of back roof,air and soil in a greenhouse located in Shenyang Agriculture University. Based on the model of the thermal balance, applying the diathermanous theory, the forecasting dynamic thermal model of the temperature of the back roof inside greenhouse was analyzed. Nonlinear regression was conducted by Matlab software, and the parameters of this model were obtained. The model reflected the characteristics of the temperature of the back roof,and provided the foundation for forecasting the temperature change and realizing the automatic control. The model provided measures and references for researching heat preservation and realizing the control in advanced of intelligent greenhouse.关键词
日光温室/热流量/后屋面温度/变化规律/预测模型Key words
solar greenhouse/thermal current amount/temperature of the back roof/change law/forecasting model分类
农业科技引用本文复制引用
何雨,须晖,李天来,山口智治..日光温室后屋面内侧温度变化规律及温度预测模型[J].现代农业科技,2012,(5):270-273,278,5.