| 注册
首页|期刊导航|郑州大学学报(医学版)|双管喉罩与普通喉罩用于不同体质指数成人患者麻醉安全性与有效性的比较

双管喉罩与普通喉罩用于不同体质指数成人患者麻醉安全性与有效性的比较

马艳丽 谢芳 韩雪萍 弓胜凯

郑州大学学报(医学版)2012,Vol.47Issue(5):716-719,4.
郑州大学学报(医学版)2012,Vol.47Issue(5):716-719,4.DOI:10.3969/j.issn.1671-6825.2012.05.038

双管喉罩与普通喉罩用于不同体质指数成人患者麻醉安全性与有效性的比较

Comparison of clinical safety and effectiveness of LMA supreme and standard LMA for different body mass index patients

马艳丽 1谢芳 1韩雪萍 1弓胜凯1

作者信息

  • 1. 郑州大学第一附属医院麻醉科,郑州,450052
  • 折叠

摘要

Abstract

Aim: To compare the applications of LMA supreme and standard LMA in patients with different body mass index. Methods:Three hundred cases were to accept urology and breast surgery,with ASA I — H were allocated into group L, group M and group H according to their body mass index. Each group was randomly allocated into either LMA-S group or LMA group. The insertion time, success rate,leak rate and sliding position rate were recorded. Results:In group H,success rate was significantly higher in LMA-S group than that of LMA group (x2 = 10. 667,P <0. 001 ), while the leak rate was lower in LMA-S group(x2 =4. 110,P =0. 043 ). However, in group L, LMA-S group had lower sliding position rate compared with that of LMA group( x2= 3. 934,P = 0. 047 ). Conclusion: It is more satisfactory and safer to use LMA-S in high body mass index patients.

关键词

全身麻醉/双管喉罩/普通喉罩/体质指数

Key words

general anesthesia/ LMA supreme/standard LMA/body mass index