砌体结构外套预制钢筋混凝土墙板加固及隔震加层振动台试验研究OA北大核心CSCDCSTPCD
Shaking table test of masonry structures strengthened with external prefabricated reinforced concrete wall and with added story isolation
为研究砌体结构外套预制钢筋混凝土墙板加固技术的加固效果,并探讨在其顶部隔震加层的可行性,进行了3个相似比为1/4模型的振动台对比试验,模型分别是加固砌体结构模型、加固后加层非隔震结构模型和加固后加层隔震结构模型。试验测试了模型结构的动力特性及其在不同地震作用下的动力响应,为了分析结构震损后的动力响应,在试验模型经历罕遇地震作用下的损伤后又继续进行不同水准地震输入试验。试验结果表明:加层非隔震结构的上部钢框架鞭稍效应非常明显;加层隔震结构有效延长了…查看全部>>
In order to research the reinforcement effects on masonry structure strengthened with external prefabricated reinforced concrete wall and investigate the possibility of added story isolation on the top of reinforced masonry structure, the shaking table tests of three 1/4. scaled models were conducted. These three models were reinforced masonry structure model, reinforced masonry structure with added story model and reinforced masonry structure with added sto…查看全部>>
王曙光;苗启松;刘金龙;刘伟庆;杜东升
南京工业大学土木工程学院,江苏南京211816北京市建筑设计研究院,北京100045南京工业大学土木工程学院,江苏南京211816南京工业大学土木工程学院,江苏南京211816南京工业大学土木工程学院,江苏南京211816
建筑与水利
砌体结构外套预制钢筋混凝土墙板振动台试验加层隔震震损结构抗震性能
masonry structureexternal prefabricated reinforced concrete wallshaking table testadded storyisolationseismic damaged structureseismic performance
《建筑结构学报》 2012 (11)
长周期地震动下隔震结构的动力行为及其性态控制研究
99-106,8
国家自然科学基金项目(51178219,50908115).