气象水文海洋仪器2012,Vol.29Issue(3):26-30,5.
南昌自动站和人工站温度观测结果差异分析
Analysis of temperature differences between automatic and manual weather station in Nanchang
摘要
Abstract
The new and old observation systems inevitably cause differences in temperature. For the sake of ensuring history data homogeneous, temperature differences between automatic and manual station have been made the comparison and quality evaluation. From the view of statistics, the 623 observation data of Nanchang meteorological station in 2008 were analyzed. And the laws of temperature variation, frequency distribution and annual and daily variation under different weather conditions were obtained. Meanwhile, the reasons that caused temperature differences were also analyzed based on meteorological viewpoints.关键词
温度差异/原因分析/自动站和人工站Key words
temperature differences/reason analysis/automatic and manual weather station分类
机械制造引用本文复制引用
陈丽红,周颖..南昌自动站和人工站温度观测结果差异分析[J].气象水文海洋仪器,2012,29(3):26-30,5.基金项目