首页|期刊导航|原子能科学技术|立式靶丸AFM表面轮廓仪系统精度测试

立式靶丸AFM表面轮廓仪系统精度测试

赵学森 高党忠 马小军 孟婕 唐永建 张林 孙涛

原子能科学技术2012,Vol.46Issue(8):1014-1018,5.
原子能科学技术2012,Vol.46Issue(8):1014-1018,5.

立式靶丸AFM表面轮廓仪系统精度测试

Measure Precision Analysis of Capsule Vertical-AFM Surface Profiler System

赵学森 1高党忠 2马小军 2孟婕 2唐永建 2张林 2孙涛2

作者信息

  • 1. 哈尔滨工业大学精密工程研究所,黑龙江哈尔滨150001
  • 2. 中国工程物理研究院激光聚变研究中心,四川绵阳621900
  • 折叠

摘要

Abstract

A capsule surface profiler system based on vertical spindle structure and atomic force microscope (AFM) was developed, and its systematic measurement tests were carried out. In order to evaluate the measurement uncertainty, the experimental studies mainly included the air-bearing spindle rotation run out error test, the system static noise test, and the comprehensive test. The rotary precision of air bearing was tested and the error curve of the spindle was obtained with a standard ball and two-step separation method. Further, this error curve was eliminated as in a systematic error. Comprehensive measurement tests of the system prove that the noise peak value of this system is about 22 nm and its RMS is about 5. 2 nm during the measurement process.

关键词

ICF靶丸/AFM/表面轮廓仪/立式轴系结构/测量精度

Key words

ICF capsule/ AFM/ surface profiler/ vertical spindle structure/ measure precision