中国工程科学2012,Vol.14Issue(8):60-63,4.
事故工况下医院中子照射器Ⅰ型堆瞬态特性研究
Study on the transient behaviours of in-hospital neutron irradiator mark 1 reactor in accident condition
朱磊 1陈立新 1江新标 1赵柱民 1周永茂2
作者信息
- 1. 西北核技术研究所,西安710024
- 2. 中国核工业集团中原对外工程公司,北京100191
- 折叠
摘要
Abstract
RELAP5/SCDAP/MOD3. 4 is used to simulate and analyze the transient proceeding of in-hospital neutron irradiator mark 1 (IHNI-1) reactor in accident condition. Large reactivity insertion accident and loss of coolent of pool accident are calculated and analyzed. The results show that IHNI-1 reactor is characterized with inherent safety. The negative coolant temperature feedback limits the nuclear power to an stable level and the reactor is safe under the accident.关键词
医院中子照射器Ⅰ型堆/事故工况/瞬态特性/RELAP5Key words
IHNI-1 reactor/accident condition/transient behaviours/RELAP5分类
能源科技引用本文复制引用
朱磊,陈立新,江新标,赵柱民,周永茂..事故工况下医院中子照射器Ⅰ型堆瞬态特性研究[J].中国工程科学,2012,14(8):60-63,4.