首页|期刊导航|中华医学杂志(英文版)|Assessment of early radial injury after transradial coronary intervention by high-resolution ultrasound biomicroscopy:innovative technology application
Assessment of early radial injury after transradial coronary intervention by high-resolution ultrasound biomicroscopy:innovative technology application
SHEN Hua JIA De-an HAN Hong-ya YU Miao MA Qian XU Xiao-han ZHOU Yu-jie LIU Yu-yang DU Jie LIU Xiao-li YAN Zhen-xian WANG Zhi-jian GAO Fei YANG Shi-wei
中华医学杂志(英文版)2012,Vol.125Issue(19):3388-3392,5.
中华医学杂志(英文版)2012,Vol.125Issue(19):3388-3392,5.DOI:10.3760/cma.j.issn.0366-6999.2012.19.005
Assessment of early radial injury after transradial coronary intervention by high-resolution ultrasound biomicroscopy:innovative technology application
Assessment of early radial injury after transradial coronary intervention by high-resolution ultrasound biomicroscopy:innovative technology application
摘要
Abstract
Background Transradial coronary intervention (TRI) introduces injury to the radial artery (RA) which will affect repeat transradial coronary procedure and the quality as a bypass conduit.We sought to compare the early radial injury after TRI between first-TRI and repeat-TRI by ultrasound biomicroscopy (UBM).Methods A total of 1116 patients who underwent the transradial coronary procedures were enrolled.The patients depending on whether for the first time to accept transradial coronary procedure were divided into first-TRI group and repeat-TRI group.The RA was examined by UBM before and one day after the procedure.Results Compared with first-TRI group,the mean RA diameter of repeat-TRI one day after the procedure decreased significantly (P <0.05).In first-TRI group,the mean RA diameter was (2.32±0.53) and (1.93±0.57) mm before procedure and one day after the procedure respectively (P <0.05).In repeat-TRI group,the mean RA diameter was (2.37±0.51) and (1.79±0.54) mm before procedure and one day after the procedure,respectively (P <0.01).Compared with first-TRI group,the mean RA diameter was reduced significantly in repeat-TRI group one day after the procedure (P<0.05).The early radial injuries and intimal thickening were compared between first-TRI and repeat-TRI.The mean intima-media thickness of RA was (0.24±0.13) mm and (0.59±0.28) mm before procedure and one day after the procedure in first-TRI group.The mean intima-media thickness of RA was (0.29±0.16) mm and (0.68±0.32) mm before procedure and one day after the procedure in repeat-TRI group.Compared with first-TRI group,the mean intimal thickening was increased significantly in repeat-TRI group one day after the procedure (P<0.05).Intimal dissection,stenosis and occlusion were all significantly greater in repeat-TRI RAs (P <0.05).Linear regression analysis revealed that diameter,repeated TRI procedure and PCI procedure were the independent predictors of intimal thickening.Conclusions RA early injuries were greater in repeat-TRI patients than in first-TRI patients.We first use high-resolution UBM imaging to demonstrate the rate of radial injury and revealed that diameter,repeated TRI procedure and PCI procedure were the independent predictors of intimal thickening.关键词
transradial intervention/ radial injury/ ultrasound biomicroscopyKey words
transradial intervention/ radial injury/ ultrasound biomicroscopy引用本文复制引用
SHEN Hua,JIA De-an,HAN Hong-ya,YU Miao,MA Qian,XU Xiao-han,ZHOU Yu-jie,LIU Yu-yang,DU Jie,LIU Xiao-li,YAN Zhen-xian,WANG Zhi-jian,GAO Fei,YANG Shi-wei..Assessment of early radial injury after transradial coronary intervention by high-resolution ultrasound biomicroscopy:innovative technology application[J].中华医学杂志(英文版),2012,125(19):3388-3392,5.基金项目
This work was supported by a grant from the Capital Chinese Medicine Technology Department Foundation (No.SF-2009-Ⅱ-12). (No.SF-2009-Ⅱ-12)