| 注册
首页|期刊导航|电网技术|支路故障后静态电压稳定裕度的估算

支路故障后静态电压稳定裕度的估算

熊宁 蔡恒 程虹

电网技术2012,Vol.36Issue(9):151-154,4.
电网技术2012,Vol.36Issue(9):151-154,4.

支路故障后静态电压稳定裕度的估算

A Method to Estimate Static Voltage Stability Margin After Branch Outage

熊宁 1蔡恒 1程虹1

作者信息

  • 1. 江西省电力科学研究院,江西省南昌市330096
  • 折叠

摘要

Abstract

A method to estimate static voltage stability margin after branch outage is proposed. Firstly, the state variables of the critical point of voltage stability after branch outage is pre-estimated by second order sensitivity, and based on the pre-estimated state variables the post-fault injected power at state variables of the critical point are solved; then the injected power is equivalent to the variation of the injected power at initial operating point under normal conditions, and according to this equivalent variation the variation of post-branch outage load margin is pre-estimated to avoid the defect of insufficient pre-estimation accuracy due to low linear sensitivity of load margin to branch admittance. The effectiveness of the proposed method is verified by simulation results of IEEE 30-bus system.

关键词

电力系统/静态电压稳定/负荷裕度/支路故障

Key words

power system/ static voltage stability/ load margin/ branch outage