化工学报2012,Vol.63Issue(10):3220-3224,5.DOI:10.3969/j.issn.0438-1157.2012.10.031
不同处理腔电极结构的高频电磁阻垢效果对比
Anti-scaling effect comparison of high-frequency electromagnetic pulses stimulation in processing chambers with different electrodes
摘要
Abstract
The software Ansoft Maxwell was used to establish the finite element model to simulate electromagnetic energy distribution in two commonly seen processing chambers. One cylindrical processing chamber was inserted with one needle electrode as anode,namely coaxial electrodes, and the other one was wrapped by spirals, both chambers were applied high-frequency electromagnetic pulses. According to the simulation data, electromagnetic energy in the processing chamber with coaxial electrodes was much stronger than that of spiral wrapped process chamber. Meanwhile, a mini-circulating water system was built and water quality experiments were conducted. Analysis results from experimental data showed that the values of electric conductivity, particle size distribution and also microscopic structures of crystal morphology among two groups and one control group were obviously different. Two kinds of processing chambers under high-frequency pulsed field had anti-scaling effects, and the processing chamber with coaxial electrodes was much better.关键词
水处理/高频电磁场/处理腔/阻垢/Ansoft MaxwellKey words
water treatment/ high-frequency electromagnetic field/ processing chamber/ anti-scaling/ Ansoft Maxwell分类
资源环境引用本文复制引用
熊兰,苗雪飞,伍懿美,陈加鹏,谢子杰..不同处理腔电极结构的高频电磁阻垢效果对比[J].化工学报,2012,63(10):3220-3224,5.基金项目
国家自然科学基金项目(51077139). (51077139)