化学工程2012,Vol.40Issue(10):10-12,24,4.DOI:10.3969/j.issn.1005-9954.2012.10.003
低温甲醇洗装置低温段系统能效优化
Optimization of system energy efficiency for low temperature section in Rectisol process
郭欣 1李士雨 2李金来2
作者信息
- 1. 河北工业大学 化工学院,天津 300130
- 2. 廊坊新奥科技发展有限公司,河北 廊坊 065001
- 折叠
摘要
Abstract
The potential of energy saving was analyzed by pinch technology for the heat exchanger network ( HEN) of the low temperature section in the Rectisol plant of a 600 000 I/a coal-to-methanol installation. On that basis, the target value and design value of utilities consumption in that unit were determined, and the segment and causes for unreasonable utilization of energy were discussed. The direction of process optimization and the potential of energy saving were revealed. Based on the profit maximization of investment on retrofit, several schemes were presented. The optimized result of the obtained final scheme is that 735. 38 kW liquid ammonia refrigerant of cold utility is saved, thus providing a reference for the optimization of the HEN in low temperature system with refrigerant as cold utility.关键词
低温甲醇洗/热集成/夹点Key words
Rectisol/heat integration/pinch分类
化学化工引用本文复制引用
郭欣,李士雨,李金来..低温甲醇洗装置低温段系统能效优化[J].化学工程,2012,40(10):10-12,24,4.