Abstract

Bursting of high temperature superheater tubes of 680 t/h power station boiler coccured twice reeently, and macroscopic examination, chemical compositions analysis and metallographic examination were investigated to find the casuse, the results showed that the failure was due to overheat which led to primary creep, then some effective prevention measures were taken.

关键词

高温过热器/爆管/超温/早期蠕变/措施

Key words

high temperature superheater/burst tube/overheating/primary creep/measure